MAX-9
Part Number: R114P80
![]()
14 month warranty
Replacement For:
- Airshields [see Hillrom]
- Analytical Industries [PSR-11-55]
- Hillrom (Airshields) [6736140]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-03]
- Pacifitech [PT-05]
- Teledyne [R13, #B-39636]
- Teleflex Medical (Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]
MAX-13-250
Part Number: R125P07
![]()
24 month warranty
Replacement For:
- Airshields [See Hillrom]
- Analytical Industries [PSR-11-917-J]
- Bio-Med Devices [10006 Sensor, M-10, M-2 Monitors, Sensor #4433, Monochrome Crossvent (use Max-13c)]
- Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent]
- Datascope [Anestar S]
- Hillrom (Airshields) [6735142]
- Hudson RCI [See Teleflex Medical]
- Invivo [9445 Sensor]
- Mercury Medical [10-103-05]
- MSA [406931, MiniOX I, II, III, 3000]
- Pacifitech [PT-11A]
- Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
- Puritan-Bennett [see Covidien]
- Teledyne [R17, #C-43690]
- Teleflex Medical [5567]
- Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent]
- VTI [100580]
MAX-14
Part Number: R116P80
![]()
14 month warranty
Replacement For:
- Devilbiss [02ANA-101 Sensor]
- Mercury Medical [10-103-13]
- MSA [806572, MiniOx 1A]
- Pacifitech [PT-26]
MAX-21i PPM O2 Sensor
Part Number: R116P07
![]()
6 month warranty
Replacement For:
- Analytical Industries [PSR-11-233]
- Teledyne [B3C]
Measurement Range: 100 - 210,000 PPM
Output @ Room Air: 140 - 260 µA
MAX-31i PPM O2 Sensor
Part Number:
![]()
8 month warranty
Replacement For:
- Contact Maxtec for Applications
Measurement Range: 100 to 210,000PPM
Output @ Room Air: 200µA ± 60µA
MAX-41A PPM O2 Sensor
Part Number: R113P16
![]()
Replacement For:
- Contact Maxtec for Applications
Measurement Range: 1 to 10,000PPM O
2 Output @ Room Air: 400µA ± 120µA
MAX-41i PPM O2 Sensor
Part Number: R109P02
![]()
Replacement For:
- Analytical Industries [PSR-12-233]
- Teledyne [B2C]
Measurement Range: 1 - 10,000 PPM
Output @ Room Air: 340 - 580 µA
MAX-65f
Part Number: R113P18
![]()
24 month warranty
Replacement For:
- Custom applications with 3-pin molex connector
- Applications needing response in milliseconds
- Custom applications with 3-pin molex connector
Measurement Range: 0 to 65 Vol%
Output Signal Range: 25 mV ± 5mV @ dry ambient air
MAX-80i
Part Number: R113P11
![]()
24 month warranty
Replacement For:
- Custom applications with 3-pin molex connector
- Applications containing high levels of CO2 or other acidic gases
- Applications needing a short response time
Measurement Range: 0.5 – 100 Vol.%
Output Signal Range: 5-15 mV @ dry ambient air
MAX-81i
Part Number: R113P20
![]()
24 month warranty
Replacement For:
- Custom applications with 3-pin molex connector
Measurement Range: 0.5 to 35 Vol%
Output Signal Range: 5-20 mV @ dry ambient air
MAX-250
Part Number: see below
![]()
24 month warranty
Replacement For:
- Maxtec [OM-25A]
- Mercury Medical [10-103-11]
- Pacifitech [PT-250]
- Teledyne [R29]
Part Numbers
- Max-250 Medical
- R125P01-002
- Max-250 Industrial/Scuba
- R125P01-003
MAX-250A
Part Number: R125P04-001
![]()
24 month warranty
Replacement For:
- Not Available [Please contact Maxtec Customer Service for applications]
MAX-250E
Part Number: see below
![]()
24 month warranty
Replacement For:
- Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
- Analytical Industries [PSR-11-917-J1]
- CareFusion (Cardinal, Viasys) [Sentry Blender]
- Fluke [VT Mobile]
- Mercury Medical [10-103-08]
- Newport Medical [e360 & e500 vents]
- Pacifitech [PT-25A]
- Teledyne [R29MED/#C-70592]
- Viasys [Sentry Blender, 66045]
Part Numbers
- Max-250E Medical
- R125P03-002
- Max-250E Industrial/Scuba
- R125P03-004
MAX-250L
Part Number: R125P13
![]()
24 month warranty
Replacement For:
- Custom applications with 3.5mm connector
- Analytical Industries [PSR-11-39-JD]
Measurement Range: 0-100% Oxygen
Output @ Room Air: 11mV ± 2.5mV @ 1013 millibar
pressure and at a temperature range of 23 ± 2 °C
MAX-250M
Part Number: R125P05-001
![]()
24 month warranty
Replacement For:
- Custom applications needing Molex Connector
MAX-250S
Part Number: R125P16-001
![]()
24 month warranty
Replacement For:
- Custom applications needing Extra Stability
MAX-401T Automotive Sensor
Part Number: R108P50
![]()
14 month warranty
Automotive Replacement For:
- AVL Analyzers
- SUN Analyzers
Measurement Range: 1 - 100 Vol.%
Output @ Room Air: 7 - 13 mV
Response Time: less than 5 seconds
MAX-402T Automotive Sensor
Part Number: R108P51
![]()
14 month warranty
Automotive Replacement For:
- Bosch Emission Analyzers
Measurement Range: 1 - 100 Vol.%
Output @ Room Air: 7 - 13.5 mV
Response Time: less than 5 seconds