866.4.Maxtec TOLL FREE
BioMed MAX Oxygen Sensors
The Maxtec line-up of replacement oxygen sensors are compatible for all major BioMed applications on the market. Our sensors are backed by excellent warranties and more stable readings and longer life.
MAX-1Part Number: R113P90
![]()
12 month warranty
Œ
Replacement For:
- Analytical Industries [PSR-11-915]
- GE (Datex-Ohmeda) [0237-2034-700 Excel Modulus, 4700 Oxicap, 5250 RGM,5100,5120,5125, 5150 Handheld Monitor, 7800]
- HP [15201A]
- Hudson RCI [See Teleflex Medical
- Mercury Medical [10-103-07]
- Pacifitech [PT-10]
- Teledyne [R15/#C-41131]
- Teleflex Medical (Hudson RCI) [5556]
- VTI [101272, 100352]
MAX-2
Part Number: R107P20
![]()
NEW 24 month warranty
Replacement For:
- Analytical Industries [PSR-11-915-1]
- Drager [Narkomed Series, Fabius GS, Fabius, GS, Tiro, 6850645, 6803290]
- HP [15201A]
- Invivo[Magnitude]
- Mercury Medical [10-103-12]
- Pacifitech [PT-24]
- Teledyne [R31]
- VTI [101372]
MAX-3
Part Number: R109P11
![]()
12 month warranty
Replacement For:
- City Technology [MOX-3]
- Mindray [VT50 Ventilator]
- Paragon Platinum SC430
- Penlon [Prima SP2]
MAX-7
Part Number: R109P09
![]()
12 month warranty
Replacement For:
- Teledyne [AX/MX300 Series, R17MED/#C-43690]
MAX-8
Part Number: R107P22
![]()
NEW 24 month warranty
Replacement For:
- Analytical Industries [PSR-11-915-3]
- GE (Datex-Ohmeda)[0237-2034-700, Excel Modulus, 5250 (ext. only),5100, 5150, 5120/5125]
- Mercury Medical [10-103-13]
- Teledyne [R32MED/#B-73463]
- VTI [101272]
MAX-9
Part Number: R114P80
![]()
14 month warranty
Replacement For:
- Airshields [see Hillrom]
- Analytical Industries [PSR-11-55]
- Hillrom (Airshields) [6736140]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-03]
- Pacifitech [PT-05]
- Teledyne [R13, #B-39636]
- Teleflex Medical (Hudson RCI) [5500, V-05, 5590, 5577, 5584, 5595, 6477]
MAX-10
Part Number: R112P10
![]()
12 month warranty
Replacement For:
- Analytical Industries [PSR-11-915-4]
- City Technology [MOX-7]
- EnviteC [OOM-110]
- GE (Datex-Ohmeda)[6050-0004-110, Modulus SE, 7900 Series, Aisys, Aestiva Series, SmartVent S-5, Aespire, Avance]
- International Technologies [M-10]
- Mercury Medical [10-103-10]
- Pacifitech [PT-20A]
- Teledyne [R30MED/#B-72939]
MAX-11
Part Number: R113P10
![]()
12 month warranty
Replacement For:
- Airshields [See Hillrom]
- City Technology [MOX-16]
- Dräger [Narkomed, Fabius GS, Fabius Series, Babylog, Evita Family, 6850645, 6803290, Cato I 8000]
- EnviteC [OOM-201]
- Hillrom (Airshields) [PSR-11-915-2]
- Hudson RCI [See Teleflex Medical]
- International Technologies [M-02]
- Invivo [Magnitude]
- Mercury Medical [10-103-07]
- Pacifitech [PT-14A]
- Teledyne [R23, #C-61139]
- Teleflex Medical (Hudson RCI) [5557, V-14]
- VTI [101372, 100352]
MAX-11i
Part Number: R113P06
![]()
12 month warranty
Replacement For:
- Drager Incubators [I8000 high temp. applications]
MAX-12
Part Number: R109P45
![]()
14 month warranty
Replacement For:
- Analytical Industries [PSR-11-917-M]
- City Technology [MOX-9]
- Datascope [Multinex Analyer, 0600-00-0002 (use Max-12f)]
- EnviteC [OOM-202]
- Hamilton [396008, 396009, Galileo, Raphael, Arabella, Aladdin, 51254, G5]
- Hudson RCI [See Teleflex Medical]
- IMT [PF300]
- International Technologies [M-04]
- Mercury Medical [10-103-06]
- MSA [472062, 470644]
- Pacifitech[PT-12A]
- Sensidyne [Acutonic Hi Frequency Jet Ventilator, 00M102]
- Siemens [9004979-E347E]
- Spacelabs [90513, Capnograph]
- Taema YR049700) Cesar 2, Horus-4
- Teledyne [R24MED, #B-62321]
- Teleflex Medical (Hudson RCI) [5556, V-12]
- VTI [103100]
MAX-12A
Part Number: R109P48
![]()
14 month warranty
Replacement For:
- Hillrom (Airshields) [Isolette Incubator]
MAX-13
Part Number: R115P10
![]()
14 month warranty
Replacement For:
- Airshields [See Hillrom]
- Analytical Industries [PSR-11-917-J]
- City Technoligies [MOX-2]
- Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent]
- Datascope [Anestar S]
- EnviteC [OOM-102-1]
- Hillrom (Airshields) [6735142]
- Hudson RCI [See Teleflex Medical]
- Invivo [9445 Sensor]
- Mercury Medical [10-103-05]
- MSA [406931, MiniOX I, II, III, 3000]
- Pacifitech [PT-11A]
- Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
- Precision Medical [PM5900, #504877]
- Puritan-Bennett [See Covidien]
- Teledyne [R17MED, #C-43690 (see Max-7 for AX/MX300 replacement]
- Teleflex Medical [5567, V-11]
- Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent]
- VTI [100580]
MAX-13-250
Part Number: R125P07
![]()
24 month warranty
Replacement For:
- Airshields [See Hillrom]
- Analytical Industries [PSR-11-917-J]
- Covidien (Puritan-Bennett) [4-020933-00, 7820 Monitor, 7200 Vent]
- Datascope [Anestar S]
- Hillrom (Airshields) [6735142]
- Hudson RCI [See Teleflex Medical]
- Invivo [9445 Sensor]
- Mercury Medical [10-103-05]
- MSA [406931, MiniOX I, II, III, 3000]
- Pacifitech [PT-11A]
- Phillips (Respironics) [Criterion Vent, Espirit Vent Lifecare (#PLV-102), 37-079 Sensor]
- Puritan-Bennett [see Covidien]
- Teledyne [R17, #C-43690]
- Teleflex Medical [5567]
- Viasys [66030 Sensor, 6400 Vent, 8400 Vent, VIP Vent]
- VTI [100580]
MAX-14
Part Number: R116P80
![]()
14 month warranty
Replacement For:
- Devilbiss [02ANA-101 Sensor]
- Mercury Medical [10-103-13]
- MSA [806572, MiniOx 1A]
- Pacifitech [PT-26]
MAX-16
Part Number: R114P70
![]()
16 month warranty
Replacement For:
- Covidien (Puritan-Bennett) [4-072214-00, 840, 740, 760 & PB2000 Tester Vents]
MAX-16HT
Part Number: R114P73
![]()
18 month warranty
Replacement For:
- Versamed [Versamed Vent]
*Note: Oxygen cell characterized by a particularly long life and extended temperature range (60°C).
MAX-17
Part Number: R116P10
![]()
12 month warranty
Replacement For:
- Analytical Industries [PSR-11-77]
- City Technology [MOX-4]
- EnviteC [00M-105]
- Hudson RCI [See Teleflex Medical]
- International Technologies [M-07]
- Mercury Medical [10-103-02]
- Pacifitech [PT-03]
- Penlon [MTS]
- Teledyne [T-7]
- Teleflex Medical [5558, V-03]
MAX-18
Part Number: R116P40
![]()
12 month warranty
Replacement For:
- Analytical Industries [PSR-11-33-1]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-01]
- Pacifitech [PT-02]
- Teledyne [C1R, #B-39022]
- Teleflex Medical [5569, V-02, 5525, 5528, 5529, 5550, 5552]
MAX-19
Part Number: R116P60
![]()
12 month warranty
Replacement For:
- Analytical Industries [PSR-11-33-1]
- Hamilton [HM-01, Veolar, Amadeus, Arabella]
- Hudson RCI [See Teleflex Medical]
- Mercury Medical [10-103-00]
- Pacifitech [PT-01]
- Teledyne [T1 #A-37016]
- Teleflex Medical [5565, 5568 C1, C-01]
MAX-24
Part Number: R109P15
![]()
16 month warranty
Replacement For:
- Stephan GmbH [Stephanie Infant Ventilator]
MAX-43
Part Number: R109P07
![]()
12 month warranty
Replacement For:
- GE (Datex-Ohmeda) [Giraffe]
MAX-47
Part Number: R112P16
![]()
12 month warranty
Replacement For:
- Teleflex Medical (Hudson RCI) [5800 Monitor, 5801 Analyzer, 5803 Sensor]
- Sensidyne [V-22]
MAX-250
Part Number: see below
![]()
24 month warranty
Replacement For:
- Maxtec [OM-25A]
- Mercury Medical [10-103-11]
- Pacifitech [PT-250]
- Teledyne [R29]
- OEM Sensor Sheet
- Specifications
- Serial Number Chart
- Frequent Buyer Program
- Frequently Asked Questions
- Material Safety Data Sheet
Part Numbers
- Max-250 Medical
- R125P01-002
- Max-250 Industrial/Scuba
- R125P01-003
MAX-250E
Part Number: see below
![]()
24 month warranty
Replacement For:
- Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
- Analytical Industries [PSR-11-917-J1]
- CareFusion (Cardinal, Viasys) [Sentry Blender]
- Fluke [VT Mobile]
- Mercury Medical [10-103-08]
- Newport Medical [e360 & e500 vents]
- Pacifitech [PT-25A]
- Teledyne [R29MED/#C-70592]
- Viasys [Sentry Blender, 66045]
- OEM Sensor Sheet
- Specifications
- Serial Number Chart
- Frequent Buyer Program
- Frequently Asked Questions
- Material Safety Data Sheet
Part Numbers
- Max-250E Medical
- R125P03-002
- Max-250E Industrial/Scuba
- R125P03-004
MAX-250ESF
Part Number: R115P85
![]()
12 month warranty
Replacement For:
- Maxtec [MaxO2+AE, OM-25AE, OM-25ME, MaxBlend, MaxVenturi]
MAX-250+
Part Number: see below
![]()
24 month warranty
Replacement For:
- Maxtec [MaxO2+A,]
- OEM Sensor Sheet
- Specifications
- Serial Number Chart
- Frequent Buyer Program
- Frequently Asked Questions
- Material Safety Data Sheet
Part Numbers
- Max-250+ Medical
- R125P02-011
- Max-250+ Industrial
- R125P02-013
MAX-250A
Part Number: R125P04-001
![]()
24 month warranty
Replacement For:
- Not Available [Please contact Maxtec Customer Service for applications]
MAX-250M
Part Number: R125P05-001
![]()
24 month warranty
Replacement For:
- Custom applications with Molex connector
MAX-250S Extra Stable
Part Number: R125P16-001
![]()
24 month warranty
Replacement For:
- Extra Stable Sensor for MAX-250 Applications
- OEM Sensor Sheet
- Specifications
- Serial Number Chart
- Frequent Buyer Program
- Frequently Asked Questions
- Material Safety Data Sheet
SpiroQuant A+ Flow Sensor
Part Number: R122P01
![]()
Sold as a 5 pack
New Features:
- DEHP Free
- 100% Tested & Inspected
- All-new reinforced design process
Replacement For:
- Dräger [843735, Narkomed, Fabius GS, Primus, 6400, Julian, Cato, Cicero, Sulla, Savina, Evita Family]
- GE [1503-3858-000]
Notice of Retraction: 4/2/12 It was brought to our attention that an incorrect image had been inadvertently used on our SpiroQuant+ Flow Sensor web page and Data Sheet. The image used was not the SpiroQuant+, but rather a Drager Spirolog. We have corrected the issue and apologize for any disruption this may have caused.
SpiroQuant H Flow Sensor
Part Number: R122P04
![]()
Sold as a 6 pack
Replacement For:
- Hamilton [H72 VR-1, Galileo, Amadeus, Arabella, Aladdin Veolar, Raphael, Sensor H7400 AccuTach, 51254, 396008]